CRE048CD1 Replace Hydraulic Oil Filter
Product SpecificationsHuahang
Part number |
CRE048CD1 |
Filter layer |
Paper |
Inner skeleton |
Punched plate |
End caps |
Plastic,Assembly |


faqHuahang
1. What harm can low-quality hydraulic oil filters cause to equipment?
Cleaning is the primary issue when hydraulic oil enters the hydraulic system for operation. Hydraulic pollution is not the dirty phenomenon that people imagine at a glance, but rather the seemingly clean oil that is actually filled with thousands of pollution particles. The filtering effect of low-quality hydraulic oil filter element is poor, and it cannot effectively prevent dirt and other impurities from entering the hydraulic system. If small impurity particles enter the hydraulic system, they will scratch the hydraulic pump (high-precision plunger pumps are commonly used on excavators, wear causes increased clearance, hydraulic pressure cannot rise, and thus work weakly), block the valve, block the oil port, and cause machine failure.
2. How to determine whether hydraulic components are damaged by regularly inspecting and replacing hydraulic oil filter elements?
When replacing the hydraulic oil filter element, please check if there are metal particles or debris at the bottom of the filter element. If there are copper or iron chips, it indicates that the hydraulic pump, hydraulic motor or valve may be damaged or about to be damaged. If there are rubber particles, it indicates that the hydraulic cylinder seal is damaged.
3. The difference between fiberglass products and ordinary hydraulic filter paper
Some of our company's products are made of fiberglass materials with higher filtration accuracy. Compared with ordinary hydraulic filter paper (ordinary wood pulp filter paper, limited by the thickness of its wood pulp fibers, the filtration accuracy is limited, while fiberglass has finer fibers, so it can achieve higher filtration accuracy), fiberglass materials have higher filtration accuracy and stronger resistance to strong pressure.
CRC410CD1 CRC120CD1 CRC220CD1 CRC240CD1 CRC330CD1 CRC340CD1
CRC415CD1 CRC420CD1 SP21217CV SP21217CDR CCA301ECD1M CA7236
CA8236 CCA302ECD1 CCA152ACD1 CCA151ACD1 CCA152ACD1 CCA151ACV1
CCA151EFV1 CCA301ACD1 CCA302ACD1 CCA301AFT1 CCA302AFT1
CCA301AFC1 CCA302AFC1 CCA301ACD1 CCA302AFD1 CCA301ACV1
CCA302ACV1 CCA301AFV1 CCA302AFV1 CCH152FT1 CCH152FC1
CCH152FD1 CCH152FV1 CCH153FT1 CCH153FC1 CCH153FV1
HOW TO replace OIL FILTERHuahang
Note
When the oil temperature is greater than 10 ℃, the wind turbine operates.
When the oil temperature is 40 ℃ and the pressure difference between the inlet and outlet of the filter exceeds 3 bar, the pressure difference sends a signal
The device emits an alarm signal, prompting the replacement of the filter element. When the oil temperature is ≤ 40 ℃, ignore the pressure
The alarm signal transmitted by the differential transmitter.
When the oil temperature exceeds 55 ℃, the oil flows through the cooler for cooling, and when the oil temperature drops to
At 45 ℃, oil flows directly into the gearbox.
Pump outlet pressure sensor or pressure gauge, used to detect the pressure of the system, system
The safety valve is set to a pressure of 12 bar. When the detected pressure exceeds 12 bar, the safety valve
The valve opens and the system overflows.


Shay